EXTERNAL WALLS Clause Examples

The 'External Walls' clause defines the responsibilities and standards related to the construction, maintenance, or modification of a building's exterior walls. It typically outlines requirements for materials, structural integrity, weatherproofing, and compliance with safety or aesthetic regulations. For example, it may specify that only approved materials can be used or that certain insulation standards must be met. The core function of this clause is to ensure that external walls meet agreed-upon quality and safety standards, thereby protecting the building's occupants and preserving the property's value.
POPULAR SAMPLE Copied 1 times
EXTERNAL WALLS.ÌýExternal walls will be done 200mm thickness brick work with hollow bricks, and complete plaster, finished with two coated cement paint.
EXTERNAL WALLS.Ìý1.3.1 Granite cladding for the bottom three levels in modern dry fixing method. 1.3.2 Aluminium cladding with fluorocarbon paint finish and heat strengthened solar reflective glazing for the curtain wall system.
EXTERNAL WALLS.ÌýWarehouse/Industrial Area: Generally comprise of horizontal broad rib PVF2 coated external sheeting with mineral wool insulation and internal lining of galvanised steel sheeting with sealed edges and finished in off white polyester-powder coating to inner face. Office Area: Polyester powder coated aluminium curtain xxxxxxx system. System is self draining, thermally broken and pressure equalised. Double glazed units comprising 6mm clear outer pane, 16mm cavity and 6mm clear inner pane with Low E coating. Insulated look-alike panels provided where vision is not required. Glazing at low level is laminated as required by current regulations. Front elevation (North) with full height curtain xxxxxxx incorporating single leaf glazed fire exit door to east end. A ribbon of windows is provided at ground and first floors including 14 No. openers at first floor and 12 No at ground. All opening windows are fitted with locking handles. Side Elevation (West) profiled steel cladding full height to warehouse area incorporating 1 No colour coated steel emergency exit door and frame with internal panic furniture and statutory signage. Office projection to North end in full height curtain xxxxxxx incorporating 1 No opening light at first floor and glazed emergency exit door at ground level. Rear elevation (South) profiled steel cladding full height incorporating 4 No electrically operated insulated sectional overhead loading doors and 2 No colour coated steel emergency exit doors and frames with internal panic furniture and statutory signage. Side Elevation (East) profiled steel cladding full height to warehouse area incorporating 1 No colour coated steel emergency exit door and frame with internal panic furniture and statutory signage. Office projection to North end in full height curtain xxxxxxx incorporating 1 No opening light at first floor, entrance door incorporating pull handles and mortise dead lock. A letter plate is provided adjacent to the main entrance door. Front (North) - Gravelled strip adjacent to building - Landscaped strip - Block paved footpath and block paved parking areas with spaces delineated in white line paint.
EXTERNAL WALLSÌýfull external envelope without internal finish and without thermal insulation (thermal insulation in accordance with the standard shall be done by the tenant and at its expense as part of the modifications). In places where this is required in accordance with the planning and building regulations, fire/smoke separation shall be installed in the region of the curtain walls.
EXTERNAL WALLS.ÌýThe external envelope shall be designed by the architect. The finish materials are: 2.13.1 Prefabricated walls with stone cladding and aluminum windows. Concrete elements covered in aluminum sheet and aluminum curtain walls with windows. 2.13.2 In the prefabricated walls the windows shall have an opening mechanism of the drei-xxx type. In the curtain walls the windows shall open outwards to the xxx position. 2.13.3 The windows shall have double glazing. On every floor emergency exit windows shall be installed, as determined by the fire service, that shall be used by all tenants of the floor. These windows shall normally be locked. A key for the windows shall be provided.
EXTERNAL WALLS.ÌýCement masonry walls to be painted in grey colour scheme. Chimney walls to be plastered & painted.
EXTERNAL WALLS.ÌýA The rear elevation is to be made good and matched in with existing. External walls will be thoroughly cleaned with local repainting as required. The external concrete xxxxx and projection will be repaired. COMPREHENSIVE XXXXXXXXXXXXX XXXXX 00, XXXXX XXXX XXXXXXXX XXXX GB-0SL/2 WEST XXXXXXX, XXXX
EXTERNAL WALLS.ÌýExternal walls of light weight sandwich panels Material characteristics
EXTERNAL WALLS.ÌýAutoclave Aerated Concrete (AAC) block or reinforced concrete walls. (b) Internal Walls AAC block or reinforced concrete walls. Ultimate Roof Reinforced concrete roof with appropriate waterproofing.
EXTERNAL WALLS.ÌýGenerally comprising 105mm facing brick; 80mm part insulated cavity; 140mm medium density concrete blockwork (fair-faced internally to Unit 38 ground floor). Stainless steel cavity wall ties. GRP white xxxxxxxx xxxxxx xxxxd to front elevation above main entrance door. Soldier course brick strings to include special bricks at window heads and/or cills. Mortar generally to be 1:1:6 with colouring agent to face brickwork; 1:3 cement mortar below d.p.c. level.